700 Kw Base Load Continuous Temporary 500kw Diesel Generator W integrated Tank

{PAGENO}

Emsa reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice.

EMSA Generator - PHP first page

E VL EM 0700

VOLVO Series
Diesel Generator Sets

700 kVA VOLVO TWD 1643 GE, EMSA EGK355-550N, 50 hz

Water Cooled

Water Cooled

50 hz

50 hz

Easy maintenance

Easy maintenance

Modular type sound-proof canopy

Modular type sound-proof canopy

3 phase

3 phase

Diesel

Diesel

Warning system for decreasing fuel with electronic fuel level sender

Warning system for decreasing fuel with electronic fuel level sender

Remote control system

Remote control system

Standby Rating for a standby engine should be sized for a maximum of 70% average load factor and roughly 200 hours per year. Stand­by power ratings should never be applied except in true emergency outage situations. With standby rated generators there is no overload capability built into the units.

Prime Power is the maximum power accessible at the variable load for an unlimited number of hours per year in a variable load setting. It is not advisable that the variable load exceed 70% average of the prime power rating during any operational period. If the engine is run­ning at 100% prime power, yearly hours should not exceed 500. Overload situations should be avoided however a 10% overload capability is available for a 1 hour period within a 12 hour cycle of operation.

Continuous Power is used in applications where suppliying power is at a constant %100 load for an unlimited number of hours each year. Continuous power rated units are most widely used in applications where the power grid is unreachable.

QUALITY STANDARDS

Our generators are manufactured in compliance with VDE 0530, BSE 4999 BS5000, IEC 34, EN12601; EN60204-1; TS ISO 8528-1 … -13; EN12100-1; EN12100-2; EN61000-6-4; EN61000-6-2; EN61000-4-11; EN61000-4-6; EN61000-4-5; EN61000-4-2; EN55011; EN55016-2-1; EN55016-2-3; EN61000-3-2; EN61000-3-3; EN55014-1; EN61000-6-2; EN61000-4-3; EN61000-4-4; EN61000-4-8; EN61000-4-11; TS EN ISO 3744; TS EN ISO 3746; TS EN 60034-1; TS EN 60034-22; TS EN ISO 3046; BS 5514; NEMA MG 21; IEC 60034, BS 4999/5000 and TS EN 60947-1..4 standards.

We have ISO 9001-2015, ISO 14001-2015, ISO 45001-2018 and ISO 1002-2006 management system certificates from Kiwa, an accredited independent quality organization.

Our generators up to 400 kw are manufactured in compliance with 2000/14/EC European noise emission directive and certified from Ente Certificazione Macchine.

We also have TS ISO 8528-4, TS ISO 8528-5, TS EN 13501-1+A1:2013 flame retardancy and TTS EN ISO 9227 certificates against anti-corrosion together with CE Declaration.

Engine Specifications

Engine Specifications

  • VOLVO series heavy duty diesel engine
  • 4 CYCLE, WATER COOLING SYSTEM, TURBOCHARGED - AFTERCOOLER INDUCTION
  • Electronic governor system
  • 12/24 volt self-starter and charger alternator
  • Changeable air, fuel and oil filter
  • Flexible fuel pipe
  • Oil discharge valve and extention pipe
  • Industrial type silencer, exhaust spiral or compensator
  • Maintenance free battery
  • Engine block water heater (in automatic models)
  • Diesel gen-set maintenance and operating instructions and electrical circuit diagram

NUMBER OF CYLINDERS

6, in line

COMPRESSION RATIO

16,5 : 1

INDUCTION

TURBOCHARGED - AFTERCOOLER

TOTAL LUBRICATION SYSTEM CAPACITY (lt)

48

TOTAL COOLANT CAPACITY (lt)

95

Alternator Specifications

Alternator Specifications

  • Brushless, single bearing, flexible disc 4 poles alternator for harmonic failure
  • H type isolation class
  • IP 21-23 protection class
  • Self exciter
  • Electronic automatic voltage regulator
  • Stator 2/3 step for harmonic failure
  • The alternator windings are protected by insulating varnish against oil and acid

VOLTAGE REGULATION (+/-)

± 1%

WEIGHT COMP. ALTERNATOR (KG)

1685

Genset Controllers

Genset Controllers

Datakom Smart 500-mk2

Datakom SMART 500-MK2

The SMART 500-MK2 is a cost effective genset controller ready for BMS integration and internet monitoring

OPTIONAL GENSET CONTROLLERS OPTIONAL

Datakom SMART 200

Datakom 200

Datakom D500

Datakom D500

Datakom D500-GSM

Datakom D500-GSM

DEEPSEA 6120

DEEPSEA 6120

DEEPSEA 7320

DEEPSEA 7320

ComAp AMF25

ComAp AMF25

Datakom SMART 200

Datakom SMART 500-MK2

Datakom D500

Datakom D500 GSM

DEEPSEA 6120

DEEPSEA 7320

ComAp AMF25

AUTOMATIC MAINS MONITORING

REMOTE MONITORING WITH SIM CARD

OPTIONAL

OPTIONAL

OPTIONAL

OPTIONAL

OPTIONAL

1 ADITIONAL OPTION (HORN, OIL-FUEL HEATER ETC.)

OPTIONAL

OPTIONAL

OPTIONAL

OPTIONAL

OPTIONAL

OPTIONAL

LIGHT WARNING AND MIMIC DIAGRAM

RS-485 COMMUNICATION

OPTIONAL

OPTIONAL

OPTIONAL

ETHERNET (TCP-IP) COMMUNICATION

OPTIONAL

OPTIONAL

GENSET CONTROLLERS FOR SYNCHRONIZATION SYSTEMS OPTIONAL

Next generation synchronizing genset controller capable of every communication and functionality.

DEEPSEA 8610

DEEPSEA 8610

DEEPSEA 8620

DEEPSEA 8620

DEEPSEA 8660

DEEPSEA 8660

ComAp InteliGen BaseBox

ComAp InteliGen BaseBox

ComAp InteliGen 200

ComAp InteliGen 200

E VL EM 0700

Canopy

  • Modular type sound-proof canopy
  • Canopy installation executed with screw and nut, without welding process
  • Epoxy and polyester powder painted canopy
  • Weatherproof canopy rating is IP 23
  • Canopy designed for easy maintenance
  • Lockable doors on both sides of canopy
  • Emergency stop button
  • Transparent panel inspection window
  • Insulation details: Non-flammeable acoustic foam
  • Nano tech cleaning system
  • Container optional

E VL EM 0700

Dimensions
(W x L x H) mm

1600x4000x2765 *

Weight (Kg)

4817

Fuel tank capacity (lt)

1050
Internal type

E VL EM 0700

Dimensions
(W x L x H) mm

1600x3200x2300

Weight (Kg)

4199

Fuel tank capacity (lt)

1050
Internal type

E VL EM 0700

External type

SILENCER OPTIONS

  • Standard industrial type
  • Critical type
  • Hospital type

CANOPY OPTIONS

  • Standard canopy
  • Super silent canopy
  • Extra süper silent canoy (thicker insulation)

GEN-SET SAFETY PROTECTION & ALARMS

  • High water temperature
  • Low oil pressure
  • High & low engine speed
  • Low radiator water level
  • Over current load
  • High & low genset voltage
  • Start/stop failure

OPTIONAL EQUIPMENTS

  • Charge ammeter
  • Moulded case circuit braker (in automatic models)
  • Hospital/Critical type silencer
  • Modular type sound-proof canopy
  • Mobile - trailer
  • Synchronization control panel for 2-16 gensets
  • 3 pole/4 pole automatic transfer panel (A.T.S.)
  • Fuel and oil heater
  • Alternator heater
  • Automatic fuel filling system
  • Fuel-water seperator filter
  • PMG warning system

wheelerdoill1998.blogspot.com

Source: https://www.emsa.gen.tr/en/products/diesel-generators/50hz-3phase/e-vl-em-0700/

0 Response to "700 Kw Base Load Continuous Temporary 500kw Diesel Generator W integrated Tank"

Post a Comment

Iklan Atas Artikel

Iklan Tengah Artikel 1

Iklan Tengah Artikel 2

Iklan Bawah Artikel